High Performance Vector Control Inverters
FRENIC5000VG7S
FEATURES
THE INVERTER
A highly efficient and effective global inverter with the functions and capabilities you need.
The industry's best control capability
Use with different control types (multi-drive function)
A wide capacity range/flexible applications
Built-in user-programmable function (option as UPAC)
Enhanced network readiness
Inverter support loader provided
Enhanced built-in functions
Upgraded maintenance/protective functions
Interactive keypad panel for simple operation
Conforms to world standards
GENERAL SPECIFICATIONS
Item
Explanation
Control performance
Speed control accuracy:
±0.005%
Speed response: 100Hz
Current response: 800Hz
Torque control accuracy (linear): ±3%
Built-in functions
Vector control of two motor
types, with V/f control for a 3rd motor
Auto-tuning
Load vibration control observer
Load weighting control
Zero speed lock control
Pulse string input (option)
Orientation control (option)
Built-in PG feedback card
RS-485 communications
I/O terminal check
Main circuit capacitor life display
Cumulative operating hours display
Touch panel
Function code data copy
Remote operation (extension cable optional)
7-language display
Jog operation
Remote/local selector
Control unit
3-phase 200V: Built-in for
55kW or less, optional for 75kW or more
3-phase 400V: Built-in for 110kW or less, optional
for 132kW or more
I/O points
Input
Output
Analog
3
3
Digital
11
6
Enclosure
15kW or less:
IP20
18.5kW or more:
IP00, IP20 is optional
INPUT VOLTAGE & PRODUCT
RANGE
Rated AC Input Voltage
3-phase
200V
[0.75to15kW]
: 3-phase 200to230V 50/60Hz
[18.5to90kW]
:
3-phase 200to220V 50Hz 3-phase
200to230V 60Hz
3-phase
400V
[3.7to15kW]
: 3-phase 380to480V 50/60Hz
[18.5to400kW]
:
3-phase 380to440V 50Hz 3-phase
380to480V 60Hz
Allowable Variation
Voltage
+10 to -15%
Frequency
+5 to -5%
Imbalance
rate in power supply voltage
2% or less
(Conforms to IEC61800-3(5.2.3))
Product Range
CT
use (for constant torque, overload capability:
150%-1min)
3-phase
200V: 0.75 to 90kW
3-phase
400V: 3.7 to 400kW
VT
use (for variable torque, overload capability:
110%-1min)
3-phase
200V: 1.5 to 110kW
3-phase
400V: 5.5 to 500kW
HT
use (for vertical transfer application, overload
capability:200%/170%-10s)