Fuji Low-Noise, Standard-Type Inverters
FRENIC5000P11S Series |
|
 |
Low-noise inverters for fans and pumps
- These inverters are specially designed for variable torque loads, such as fans and pumps.
- An automatic energy-saving function is included for simple energy-saving operation.
- An interactive keypad panel is incorporated as standard equipment, allowing you to operate the inverter without a manual.
|
|
|
|
| |
|
|
| |
| |
| Series |
FRENIC5000P11S |
| Output overload capability |
110% of rated current for 1min |
| Braking torque |
Regenerative braking |
20% or more
(11 to 22kW)
10 to 15%
(30kW or more) |
| DC injection braking |
Starting frequency: 0.1 to 60Hz (adjustable)
Braking time: 0 to 30s (adjustable)
Braking voltage: 0 to 100% (adjustable) |
| Acceleration/deceleration time |
0.01 to 3600s
(Acceleration/deceleration can be set independently) |
| Multi frequency control |
16 steps |
| Frequency setting signal |
0 to ±5V DC, 0 to ±10V DC, 4 to 20mA |
| Protective functions |
Stall prevention, overcurrent, instantaneous power failure or undervoltage, overvoltage, inverter overheating, external alarm (tripping of external thermal overload relay), motor overload (tripping of electronic thermal overload), communications error, CPU error, memory error, short-circuit, ground fault, blown out fuse, input open-phase protection, output open-phase protection |
| Alarm relay output |
SPDT contact |
| Enclosure and cooling method |
Totally enclosed fan cooling type [IP40, except fan]
(5.5 to 22kW)
Fan cooling type [IP00]
(30kW or more)
For inverters of 30kW or more, the totally enclosed type [IP20] is optional. |
|
|
|
| |
|
|
| |
INPUT
VOLTAGE & PRODUCT RANGE
|
|
Rated AC Input Voltage |
| Nominal input voltage |
Capacity |
AC input voltage and frequency |
| 3-phase 200V |
22kW or less |
200 to 230V 50/60Hz |
| 30kW
or more |
200
to 220V 50Hz
220 to 230V 50Hz
(Order individually)
200 to 230V 60Hz |
| 3-phase 400V |
22kW or less |
380 to 480V 50/60Hz |
| 30kW
or more |
380
to 440V 50Hz
380 to 480V 60Hz |
|
| |
Allowable
Variation |
| Voltage |
+10%
to -15% |
| Frequency |
+5% to -5% |
| Imbalance
rate in power supply voltage |
2% or less
(Conforms to IEC61800-3(5.2.3)) |
|
| |
Product
Range |
| 3-phase
200V: 5.5 to 110kW |
| 3-phase
400V: 5.5 to 500kW |
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|