| Ring Blowers |
| FEATURES |
 |
Low noise
An ideally designed blower section and built-in, high-efficiency silencers in the intake and outlet ports greatly reduce running noise.
Dust-tight bearings
An oil seal is provided between the blower and the bearings, and grease-sealed bearings are used.
Compact, lightweight unit with high airflow pressure
A forward-positioned fin structure delivers high airflow pressure in spite of the compact size and light weight. |
|
| |
| GENERAL
SPECIFICATIONS |
| Series |
Type |
Input
voltage
(V) |
Frequency
(Hz) |
Maximum
delivery air flow pressure
(kPa) |
Maximum
delivery air flow rate
(m3/min) |
| 50Hz |
60Hz |
50Hz |
60Hz |
|
Standard
single-phase |
VFC068P
to
VFC408P |
|
50/60 |
1.62
to
9.81 |
2.26
to
13.2 |
0.42
to
2.05 |
0.48
to
2.45 |
|
Standard
3-phase |
VFC086A
to
VFC906A |
|
3.73
to
25.5 |
4.85
to
31.4 |
0.47
to
13.0 |
0.56
to
15.5 |
|
Low-noise
single-phase |
VFC086PN
to
VFC407PN |
|
3.73
to
9.81 |
4.85
to
13.2 |
0.47
to
2.05 |
0.56
to
2.45 |
|
Low-noise
3-phase |
VFC086AN
to
VFC906AN |
|
3.73
to
25.5 |
4.85
to
31.4 |
0.47
to
13.0 |
0.56
to
15.5 |
|
Special
voltage |
VFC086A-4Z
to
VFC806A-4Z |
|
3.73
to
25.5 |
4.85
to
33.3 |
0.47
to
8.7 |
0.56
to
10.3 |
|
Increased
safety |
VFC405C
to
VFC605C |
|
9.61
to
18.3 |
12.1
to
23.1 |
1.95
to
4.2 |
2.4
to
5.0 |
|
Note
: UL recognized /CLA certified series, waterproof series,
large airflow rate series,
and high airflow pressure series are also available.
|
| |
| TYPICAL
APPLICATIONS |
| • |
Powder transport |
• |
Ventilation and cooling |
| • |
Suction |
• |
Air bubbling (aerated baths) |
| • |
Dust collection |
• |
Liquid bottling |
| • |
Floating |
• |
Spraying |
| • |
Air tension |
|
|
|
|
| |
|
| |
|
|
| |
|
|
| |
| Turbo Blowers |
FEATURES |
 |
VCP high-temperature type
A highly efficient, heat-resistant design enables the transport of gases from normal temperatures all the way up to 110oC.
VCT type
The impellers and blower section are made of aluminum alloy (except for the VCT243A(B), which has steel-plate impellers, and the VCT263A(B), 283A(B), and 333A(B), in which the impeller side plates are made of steel plates).
VCS type
These compact, multi-stage blowers offer both high airflow pressure and a high airflow rate. |
|
| |
GENERAL SPECIFICATIONS |
| Series |
Type |
Input voltage
(V) |
Motor output (kW) |
Maximum delivery
air flow
pressure
(kPa) |
Maximum delivery
air flow rate
(m3/min) |
VCT Series
Large air flow rate type |
VCT243A
to
VCT393A
(For 50Hz only) |
3-phase
200 |
0.75
to
11 |
2.1
to
8.0 |
25
to
65 |
VCT243B
to
VCT393B
(For 60Hz only) |
0.75
to
11 |
2.1
to
8.0 |
25
to
70 |
VCP Series
High temperature type |
VCP062P |
Single-phase
100 |
0.18 /0.31 |
1.1
/1.6 |
5.5
/6.5 |
| VCP062A |
3-phase |
| VCP082A |
0.50
/0.85 |
1.9
/2.7 |
11
/13 |
VCS Series
High air flow pressure type |
VCS402A
to
VCS702A
(For 50Hz only) |
3-phase
200 |
0.75
to
3.7 |
3.3
to
14 |
8
to
13 |
VCS402B
to
VCS702B
(For 60Hz only) |
0.75
to
3.7 |
3.3
to
15 |
14
to
15 |
|
| |
TYPICAL APPLICATIONS |
| Series |
Applications |
VCT Series
large airflow rate blowers |
Dust collection, powder transport, ventilation, exhaust, forced air cooling, drying |
VCP Series
high-temperature blowers |
Dust collection, forced air cooling, combustion, conveyor systems |
VCS Series
high airflow pressure blowers |
Powder transport, exhaust, forced air cooling, combustion, conveyor systems |
|
| |
 |
| |
|
|
| |
|
|
| |
| Outer rotor Fans and Propeller Fans |
FEATURES |
 |
Outer rotor fans
These pressurized ventilation fans integrate an outer rotor type motor (in which the rotor is placed outside the stator) and impellers.
Propeller fans
High performance is achieved in these fans through the use of "Excellent Power" motors. |
|
| |
GENERAL SPECIFICATIONS |
| Outer rotor Fans |
| Series |
Impeller diameter
(cm) |
Input voltage
(V) |
Nominal output
(W) |
Air flow rate
(m3/min) |
Maximum permissible static pressure
(Pa) |
| 50Hz |
60Hz |
50Hz |
60Hz |
Single-phase standard type |
30 to 40 |
100 |
50 to 200 |
32 to 72 |
37 to 83 |
100 |
| 200 |
50 to 200 |
| 3-phase standard type |
30 to 50 |
|
50 to 750 |
32 to 170 |
37 to 200 |
100 to 200 |
3-phase indoor type |
30 to 50 |
50 to 270
(50Hz)
80 to 400
(60Hz) |
34 to 113 |
40 to 135 |
130 to 200 |
| 3-phase low-temperature type |
30 to 50 |
50 to 270
(50Hz)
80 to 400
(60Hz) |
|
| |
| Propeller Fans |
| Series |
Impeller diameter
(cm) |
Input voltage
(V) |
Nominal output
(W) |
Air flow rate
(m3/min) |
Maximum permissible static pressure
(Pa) |
| 50Hz |
60Hz |
50Hz |
60Hz |
3-phase round frame type |
40 to 60 |
|
150 to 450
(50Hz)
250 to 600
(60Hz)
|
65 to 180 |
74 to 200 |
120 to 160 |
130 to 170 |
| 3-phase agricultural type |
100 |
400 |
330 |
7 |
|
| |
TYPICAL APPLICATIONS |
| |
Applications |
| Outer rotor fans |
Air conditioning units, power distribution panel cooling, oil coolers, ventilation, greenhouses, poultry houses, and livestock sheds |
| Propeller fans |
|
| |
 |
| |
|
|
|